Keeprite Dc90 Manual

Dc90

  1. Keeprite Dc90 Manual Parts
Keeprite dc90 furnace manualManual

I need your advice regarding Keeprite furnace problems.I think the brand is named for keeping right up the employment and profit of the HVAC repair guys. Keeprite N9mp Manual - Lighter2case.wpxnews.com Keeprite N9mp Manual If you are looking for a eBook Keeprite n9mp manual kehyike in pdf plan accordingly you get befall to ethical online largest archive. Read Full Source. Keencut javelin cutter owners manual keep 57 manual dr wendt keeprite dc90 manual keeprite ps90 manual keepsake scrapbooking design manual keepsakes scrapbooking designer deluxe manual keepwatch 6 home alarm instruction manual keeway service manual keeway venus manual keeyway hurricane service manual kef kht2005.2 manual kef kit 100 manual.

Keeprite Dc90 Manual Parts

Error CodesWhat this meansHow to fix it
Heartbeat LED pattern on solidThe control is locked out and will auto-reset after 1 hour.Reset power to clear the lockout.
Two LED flashesPressure switch didn’t open.Obstructed pressure tubing; a pressure switch that’s stuck closed.
Three LED flashesThe low-pressure switch did not close or has reopened.Proper vent sizing; air leak; restricted vent; clogged condensate drain; low input gas pressure; excessive wind; improper pressure switch wiring; water in vent piping; disconnected or obstructed pressure tubing.
Four LED flashesLimit circuit fault.Loose blower wheel; defective switch or connections; improper minimum- or maximum-heat gas input adjustment; dirty filter or restricted duct system; improper limit switch.
Five LED flashesAbnormal flame-proving signal.Leaky gas valve; stuck-open gas valve.
Six LED flashesIgnition proving a failure.Low inlet gas pressure; control ground continuity; gas valve defect; defective hot surface igniter; oxide buildup on the flame sensor; inadequate flame carryover; flame sensor mustn’t be grounded.
Seven LED flashesLimit circuit lockout.Control will auto-reset after 3 hours. Refer to status code #4.
Eight LED flashesGas heating lockout.Gas valve stuck closed on control.
Nine LED flashesMedium pressure switch, high-pressure switch, or PSR relay didn’t close or was reopened.Refer to status code #3.
Ten LED flashesPolarity.Correct line voltage polarity.
Status codes 1 + 2Blower on after power up.Normal operation.
Status codes 1 + 5Blower motor lockout.Control will auto-reset after 3 hours. Refer to status code #4 + 1.
Status codes 3 + 5Gas valve fault.RED, YELLOW, or ORANGE wire at the gas valve.
Status codes 4 + 1Blower motor fault.Blower failed to reach 250 RPM, or the blower failed to communicate within the prescribed time limits.
Status codes 4 + 2Inducer motor fault.Proper vent sizing; restricted vent; failed inducer motor; improper motor wiring; a blockage in the tubing to the pressure switch assembly.
Status codes 4 + 3The low or medium pressure switch is open while the medium or high-pressure switch is closed.Low inlet gas pressure; clogged condensate drain; improper pressure switch wiring; water in vent piping; low or medium pressure switch stuck open; disconnected or obstructed pressure tubing.
Status codes 6 + 1Ignition lockout.Control will auto-reset after 3 hours. Refer to status code #6.